HZ56-2 *

AC/DC Current Clamps

This AC/DC Current Probe is used to measure currents from 1mA to 30 A over a broad frequency range. The measurement principle is based on the Hall Effect that registers the magnetic field generated by the current flow. Even for complex waveforms a high degree of measurement accuracy is achieved. The output voltage is proportional to the measured current and well suited to be displayed on an oscilloscope. The current probe complies with the safety standards defined in IEC/EN 61010.


Measurement range: ±30 ADC / 20 AAC 
Accuracy: ±1% ±2mA 
Frequency range: DC to 100 kHz 
Resolution: 1 mA 
Output voltage: 100 mV/A 
Load impedance: > 100 kΩ 
Voltage stability: 3.7 kV / 50 Hz / 1 minute 
Connection: BNC-Cable, 2 m 

* Product discontinued; Successor: HZO50




Manuals (1) 
HZO40

Differential Probe 10:1

Technical specifications at 23 °C ±2 °C


Bandwidth: 200 MHz 
Attenuation ratio: 10:1 
Rise time (10…90%): 1.75 ns 
Gain accuracy ±1% 
Max. Input Voltage per Input: ±60 V 
Max. Differential Input Voltage (DC + peak AC): ±20 V 
Max. Common Mode Input Voltage: ±60 V 
Input impedance  
   Between Inputs: 1 MΩ II 3.5 pF 
   Each Input to Ground: 500 kΩ II 7 pF 
Output Voltage (into 50 Ω): ±2 V 
Offset (typical) ±2 mV 
CMRR (typical): -80 dB at 60 Hz
-50 dB at 10 MHz 
Battery operation: 9 V battery 6LR61 
Battery life (typical): 7.5 h 
Input for an external power supply: USB Power adapter cable (5…9 VDC/200 mA) 


Datasheets (4)Manuals (1)
Professional articles (5) 
HZO41

Differential Probes 10:1

Technical specifications at 23 °C ±2 °C


Bandwidth: 800 MHz 
Attenuation ratio: 10:1 
Rise time (10…90 %): 437 ps 
Gain accuracy ±2 % 
Max. Input Voltage per Input: ±40 V 
Max. Differential Input Voltage (DC + peak AC): ±15 V 
Max. Common Mode Input Voltage: ±30 V 
Input impedance  
   Between Inputs: 200 kΩ II 1 pF 
   Each Input to Ground: 100 kΩ II 2 pF 
Output Voltage (into 50 Ω): ±1.5 V 
Offset (typical) ±5 mV 
CMRR (typical): -60 dB at 60 Hz
-15 dB at 500 MHz 
Battery operation: 9 V battery 6LR61 
Battery life (typical): 4.5 h 
Input for an external power supply: USB Power adapter cable (5…9 VDC/300 mA) 


Datasheets (4)Manuals (1)
HZO50

AC/DC Current Probe 30 A

This AC/DC current probe is used to measure currents from 1mA to 30 A over a broad frequency range. The measurement principle is based on the Hall Effect that registers the magnetic field generated by the current flow. Even for complex waveforms a high degree of measurement accuracy is achieved. The output voltage is proportional to the measured current and well suited to be displayed on an oscilloscope. The current probe complies with the safety standards defined in IEC/EN 61010.


Specifications  
Measurement range: ± 20 Arms/30 Ap 
Accuracy: ± 1% from measurement value ± 2 mA 
Bandwidth: DC…100 kHz (0,5 dB) 
Resolution: ± 1 mA 
Output voltage: 100 mV/A 
Load impedance: › 100 kΩ II ≤ 100 pF 
Max. Voltage: 300 Vrms (AC or DC) 
Output cable/Connector: 2m (50 Ω)/BNC 
Measuring category: CAT III 


Datasheets (4)Manuals (1)
HZO51

AC/DC Current Probe 100/1000 A

This AC/DC current probe is used to measure currents from 100mA to 1000A over a broad frequency range. The measure­ment principle is based on the Hall Effect that registers the magnetic field generated by the current flow. Even for complex waveforms a high degree of measurement accu­racy is achieved. The output voltage is proportional to the measured current and well suited to be displayed on an oscilloscope. The current probe complies with the safety standards defined in IEC/EN 61010.Specifications


Specifications  
Measurement range: ±100 Arms/1000 Arms 
Accuracy: ±1% from measurement value ±0.1 A/±0.5 A 
Bandwidth: DC…20 kHz 
Resolution: ±100 mA/±500 mA 
Output Voltage: 10 mV/A/1 mV/A 
Load impedance: >100 kΩ II ≤100 pF 
Max. Voltage: 300 Vrms (AC or DC) 
Output cable/Connector: 2 m (50 Ω)/BNC 
Measuring category: CAT III 


Datasheets (4)Manuals (1)
HZ350

Probe 10:1

Attenuation ratio: 10:1 
Bandwidth: 350 MHz 
Rise time: <1.0 ns 
Input impedance: 10 MΩ II 12 pF 
Max. Voltage: 400 V (DC + peak AC) 
LF compensation: 1 Trimmer 
RF compensation: 2 Trimmer 
Cable length: 1.2 m 
Probe factor identification: automatically after connection 
Measuring category: CAT I 


Datasheets (4)Manuals (1)
Knowledge Base (1) 
HZ355

Probe 10:1

Attenuation ratio: 10:1 
Bandwidth: 500 MHz 
Rise time: <700 ps 
Input impedance: 10 MΩ II 9.5 pF 
Max. Voltage: 400 V (DC + peak AC) 
LF compensation: 1 Trimmer 
RF compensation: 2 Trimmer 
Cable length: 1.3 m 
Probe factor identification: automatically after connection 
Measuring category: CAT I 


Datasheets (4)Manuals (1)
Professional articles (8)Knowledge Base (1)
HZ200

Probe 10:1

Attenuation ratio: 10:1 
Bandwidth: 250 MHz 
Rise time: <1.4 ns 
Input impedance: 10 MΩ II 12 pF 
Max. Voltage: 400 V (DC + peak AC) 
LF compensation: 1 Trimmer 
RF compensation: 2 Trimmer 
Cable length: 1.2 m 
Probe factor identification: automatically after connection 
Measuring category: CAT I 


Datasheets (4)Manuals (1)
Knowledge Base (1) 
HZ51

Probe 10:1

Attenuation ratio 10:1 
Bandwidth 150 MHz 
Rise time <2.4 ns 
Input impedance 10 MΩ II 12 pF 
Max. Voltage 600 V (DC + peak AC) 
LF compensation: 1 Trimmer 
RF compensation: 1 Trimmer  
Cable length 1.2 m 
Measuring category CAT I 


Datasheets (4)Manuals (1)
Knowledge Base (1) 
HZ52

Probe 10:1

Attenuation ratio 10:1 
Bandwidth 250 MHz 
Rise time <1.4 ns 
Input impedance 10 MΩ II 10 pF 
Max. Voltage 600 V (DC + peak AC) 
LF compensation 1 Trimmer 
RF compensation 2 Trimmer 
Cable length 1.2 m 
Measuring category CAT I 


Datasheets (4)Manuals (1)
Knowledge Base (1) 
HZ53

Probe 100:1

Attenuation ratio 100:1 
Bandwidth 100 MHz 
Rise time <3.5 ns 
Input impedance 100 MΩ II 4.5 pF 
Max. Voltage 1200 V (DC + peak AC) 
LF compensation 1 Trimmer 
Cable length 1.2 m 
Measuring category CAT I 


Datasheets (4)Manuals (1)
Knowledge Base (1) 
HZ154

Probe 1:1 / 10:1

Attenuation ratio 1:1 
Switchable 10:1 
Bandwidth 10/100 MHz 
Rise time  ‹ 35/3.5 ns 
Input impedance 1/10 MΩ II 82/12 pF 
Max. voltage (10:1) 600 V (DC + peak AC) 
LF compensation 1 Trimmer at 10:1 
RF compensation 2 Trimmer at 10:1 
Cable length 1.2 m 
Measuring category CAT I 


Datasheets (4)Manuals (1)
Knowledge Base (1) 
HZO20

Probe 1000:1

Attenuation ratio: 1000:1 
Bandwidth: 400 MHz 
Rise time: ‹ 900 ps 
Input impedance: 50 MΩ II 7.5 pF 
Max. Voltage: 1000 Vrms 
LF compensation: 1 Trimmer 
RF compensation: 1 Trimmer 
Cable length: 1.3 m 
Probe factor identification: automatically after connection 
Measuring category: CAT II 


Datasheets (4)Manuals (1)
HZO30

Active Probe 10:1

Attenuation ratio: 10:1 
Bandwidth: 1GHz 
Rise time: 600 ps 
Input impedance: 1 MΩ II 0.9 pF 
Max. Input voltage: 20 V 
Input Dynamic Range: ± 8 V 
Cable length: 1.3 m 
Oscilloscope Input Coupling: 50 Ω 
External Power Supply included 


Datasheets (4)Manuals (1)
Professional articles (7) 
HZO10

Probe 10:1

Attenuation ratio: 10:1 
Bandwidth: 250 MHz 
Rise time: <1.4 ns 
Input impedance: 10 MΩ II 15 pF 
Max. Voltage: 400 V (DC + peak AC) 
LF compensation: 1 Trimmer 
RF compensation: 2 Trimmers 
Cable length: 1.2 m 
Probe factor identification: automatically after plugging 
Measuring category: CAT I 


Datasheets (4)Manuals (1)
HZ100

Differential Probe 20:1 / 200:1

Technical specifications at 23 °C ± 2 °C


Differential input voltage (DC + peak AC) max.: ±700 V 
Max. input voltage per input: 600 Vrms 
Attenuation ratio: 20:1 
Selectable: 200:1 
Bandwidth: 30/40 MHz 
Rise time: 12/9 ns 
Input impedance: 8 MΩ II 1.2 pF 
Output impedance: 50 Ω 
Max. output Voltage: ±3.5 V at 1 MΩ 
Max. noise: 2 mV 
Accuracy after 1 min: ±3% (18…30 °C) 
Common mode rejection DC/AC 1 MHz: 70 dB/>50 dB 
Inputs (CAT III): 2 safety connectors 
Input leads: 2 test leads 50 cm with spring hooks 
Battery operation: 9 V battery 6LR61 
Input for an external power supply: 12…14 Vdc/30 mA 


Datasheets (4)Manuals (2)
HZ109

Differential Probe 1:1/10:1

Technical specifications at 23 °C ± 2 °C


Differential input voltage (DC + peak AC) max.: ±3,5 V/35 V 
Max. input voltage per input: 100 Vrms 
Attenuation ratio: 1:1 
Selectable: 10:1 
Bandwidth: 30/40 MHz 
Rise time: 12/9 ns 
Input impedance: 8 MΩ II 1.2 pF 
Output impedance: 50 Ω 
Max. output Voltage: ±3.5V at 1 MΩ 
Max. background noise at x1: <8 mVrms 
at x10: <2 mVrms 
Accuracy after 1 min: ±3 % (18…30 °C) 
Common mode rejection DC/AC 1 MHz: 70 dB/>50 dB 
Inputs (CAT III): 2 safety connectors 
Input leads: 2 test leads 50 cm with spring hooks 
Battery operation: 9 V battery 6LR61 
Input for an external power supply: 12…14 Vdc/30 mA 


Datasheets (4)Manuals (2)
HZ115

Differential Probe 100:1/1000:1

Technical specifications at 23 °C ± 2 °C


Differential input voltage (ACrms): 1000 V 
(DC + peak AC) max.: ±1400 V*) 
Max. input voltage per input: ±1400 V*) 
Attenuation ratio: 100:1 
Selectable: 1000:1 
Bandwidth: 20/30 MHz 
Rise time: 17/12 ns 
Input impedance: 60 MΩ II 1.5 pF 
Output impedance: 50 Ω 
Max. output Voltage: ±1.5 V at 1 MΩ 
Max. background noise: 2 mV 
Accuracy after 1min: ±3 % (18…30 °C) 
Common mode rejection DC/AC 1 MHz: 70 dB/>50 dB 
Inputs (CAT III): 2 safety connectors 
Input leads: 2 test leads 75 cm with safety test clips 
Battery operation: 9 V battery 6LR61 
Input for an external power supply: 12…14 Vdc/30 mA 

*) due to test clip 1000 V CAT III