Accessories for Spectrum Analyzers

HZ520

Plug-in Antenna

Telescopic Antenna for RF reception
BNC connection



HZ525

Termination

Frequency range: DC…6GHz 
Impedance: 50Ω 
VSWR: 1.05 (DC…1GHz) 
 1.1 (1…4GHz) 
 1.2 (4…6GHz) 
Power: 1 W aver. 
Connection: N-male 



Knowledge Base (1) 
HZ530

EMV Near-Field Probe Set up to 1GHz

The HZ530 Probe Set consists of three active broadband probes for EMI diagnosis. The probes are designed for connection to a HAMEG spectrum analyzer with input impedance of 50 Ω. The probes can be powered by the spectrum analyzer or batteries. The slim format ensures easy access to the test object even in cramped test environments.

 

The H-field probe provides a signal that is proportional to the magnetic field strength to the spectrum analyzer. This makes it possible to localize sources of interference with relatively high precision.

 

The high-impedance probe can be used to determine interference levels on contacts, lines and printed circuit boards.

 

The E-field probe is the most sensitive of the three probes. It can be used to assess the total effect of shielding and filtering in a tested unit.


Technical specifications at 23°C ±2°C


Frequency Range: 100kHz…1GHz 
Supply Voltage: 6Vdc from Spectrum Analyzer or batteries, 4x Mignon/AA, not included 
Supply Current: approx. 10…24mAdc 
Probe Dimensions: 40 x 90 x 195mm (W x H x D) 
Cases: plastic, internal electrical shielding 
Set includes: 1 E-field probe
1 H-field probe
1 high-impedance probe
1 BNC cable 1.5 m
1 power cable
Operator’s Manual
Robust carrying case 



Datasheets (4)Manuals (1)
HZ540/HZ550

EMV Near-Field Probe Set up to 3GHz

The HZ540/550 are the ideal toolkits for the investigation of RF electromagnetic fields. They are indispensable for EMI pre-compliance testing during product development, prior to third party testing. The sets include 3 or 5 hand-held probes with built-in preamplifier covering the frequency range from <1 MHz to approx. 3000 MHz.

 

The probes of the basic set HZ540 include one magnetic field probe, one electric field probe, and a high impedance probe. In addition to the HZ550 features an optional μmagnetic field probe and an antenna. All probe outputs are matched to the 50 Ω inputs of spectrum analyzers or RFreceivers.




Datasheets (4)Manuals (1)
Knowledge Base (1) 
HZ541 *

1GHz VSWR Bridge

This unit is used to measure the voltage standing wave ratio (VSWR) and the reflection coefficient of a device under test with an impedance of 50 Ω.

Typical test objects include attenuators, terminations, frequency switches, amplifiers, cables and mixers. The measurement range is specified from 150 kHz…1GHz/100 kHz…3 GHz.


Technical specifications (temperature range from +10°C to +45°C)


Frequency range: 150 kHz…1.05GHz 
Impedance: 50Ω 
Directivity: › 28 dB (150 kHz…300 kHz)
› 35 dB (300 kHz…1 GHz) 
Reflection loss
at DUT port: 
›20dB 
Insertion loss
IN→ OUT: 
20 dB (150 kHz…300 kHz) 
IN→ OUT: 17 dB (300 kHz…1 GHz) 
IN→ DUT: 1.7 dB 
DUT→ OUT: 16dB 
Max. Power Dissipation: +26dBm 
Connectors: N (female) 
Dimensions (W x H x D,
without connectors): 
151.5 x 38 x 29.5mm 
  
Weight: approx. 650 g 
Temperature range: +10 °C…+45 °C 

HZ525 (Termination 50 Ω 1W), N male to N male (2 ea.),Carrying case (265 x 225 x 50 mm WxHxD)


* Product discontinued; Successor: HZ547




Manuals (1)Knowledge Base (1)
HZ547

VSWR Bridge

This unit is used to measure the voltage standing wave ratio (VSWR) and the reflection coefficient of a device under test with an impedance of 50 Ω.

Typical test objects include attenuators, terminations, frequency switches, amplifiers, cables and mixers. The measurement range is specified from 150 kHz…1GHz/100 kHz…3 GHz.


Technical specifications (temperature range from +10°C to +45°C)


Frequency range: 100 kHz…3GHz 
Impedance: 50Ω 
Directivity: › 28 dB (100 kHz…300 kHz)
35 dB (300 kHz…1 GHz)
› 30 dB (1GHz…3GHz) 
Reflection loss
at DUT port: 
›20dB 
Insertion loss
IN→ OUT:20 dB (100 kHz…300 kHz) 
IN→ OUT: 18 dB (300 kHz…3 GHz) 
IN→ DUT: 1.7dB 
DUT→ OUT: 16dB 
Max. Power Dissipation: +26dBm 
Connectors: N (female) 
Dimensions (W x H x D,
without connectors): 
150 x 68 x 29.5mm 
  
Weight: approx. 650 g 
Temperature range: +10 °C…+45 °C 

HZ525 (Termination 50 Ω 1W), N male to N male (2 ea.),Carrying case (265 x 225 x 50 mm WxHxD)




Manuals (1)Knowledge Base (2)
HZ560

Transient Limiter

The HZ560 Transient Limit protects the input circuits of spectrum analyzers and test receivers.

The input of the Transient Limiter is connected via BNC cable to the signal source. The output can be connected directly to the spectrum analyzer.


Technical specifications at 23°C ± 2°C


Frequency range: 150 kHz…30 MHz
a = 10 dB + 1.5/0.5 dB
at f <1 kHz a ≥90 dB
at f <10 kHz a ≥50 dB 
Insertion loss: 10 dB (+1.5/0.5 dB) 
Max. input level: +33 dBm (2 W, average) 
Max. input voltage: ±50 Vdc 
VSWR: 1.5:1 or better 
Connections: BNC (input and output) 
Dimensions: 67 x 32 x 32 mm (W x H x D) 



Datasheets (2)Manuals (1)
HZ575

Converter

HZ575 is a 75Ω to 50Ω converter enabling measurement in 75Ω systems in connection with 50Ω input impedance spectrum analyzers.

The 75Ω input is a 75Ω BNC socket which is AC coupled internally. The output is a 50Ω N male connector which is DC coupled. HZ575 can also be used for reverse operation converting 50Ω to 75Ω.


Technical specifications


Frequency range: 5 MHz…1.2 GHz 
Insertion loss: less than 1 dB 
Max. Level/Voltage at 75 Ω connector: +10 dBm / ±20 Vdc 
Max. Level/Voltage at 50 Ω connector: +10 dBm / 0 Vdc 
Dimensions: 25 x 25 x 58 mm (W x H x D) 
Weight: 100 g 



Manuals (1)Knowledge Base (1)


 
 

The new waveform reference – the new 25/50MHz Arb-Generator HMF Series +++ Product of the Year 2010 – the new DSO/MSO 350MHz +++ Versatility – one for all – the new high performance power supply HMP Series +++ 
© 2011 HAMEG Instruments GmbH | Imprint | Terms & Conditions