Accessories for Spectrum Analyzers |  | HZ520
Plug-in Antenna
 | Telescopic Antenna for RF reception
|  | BNC connection |

| |  | HZ525
Termination
| Frequency range: | DC…6 GHz | | Impedance: | 50 Ω | | VSWR: | 1.05 (DC…1 GHz) | | | 1.1 (1…4 GHz) | | | 1.2 (4…6 GHz) | | Power: | 1 W aver. | | Connection: | N-male |

| |  | HZ530
EMV Near-Field Probe Set up to 1GHz
The HZ530 Probe Set consists of three active broadband probes for EMI diagnosis. The probes are designed for connection to a HAMEG spectrum analyzer with input impedance of 50 Ω. The probes can be powered by the spectrum analyzer or batteries. The slim format ensures easy access to the test object even in cramped test environments.
The H-field probe provides a signal that is proportional to the magnetic field strength to the spectrum analyzer. This makes it possible to localize sources of interference with relatively high precision.
The high-impedance probe can be used to determine interference levels on contacts, lines and printed circuit boards.
The E-field probe is the most sensitive of the three probes. It can be used to assess the total effect of shielding and filtering in a tested unit. 
Technical specifications at 23 °C ±2 °C 
| Frequency Range: | 100 kHz…1 GHz | | Supply Voltage: | 6 Vdc from Spectrum Analyzer or batteries, 4x Mignon/AA, not included | | Supply Current: | approx. 10…24 mAdc | | Probe Dimensions: | 40 x 90 x 195 mm (W x H x D) | | Cases: | plastic, internal electrical shielding | | Set includes: | 1 E-field probe 1 H-field probe 1 high-impedance probe 1 BNC cable 1.5 m 1 power cable Operator’s Manual Robust carrying case |

| |  | HZ540/HZ550
EMV Near-Field Probe Set up to 3GHz
The HZ540/550 are the ideal toolkits for the investigation of RF electromagnetic fields. They are indispensable for EMI pre-compliance testing during product development, prior to third party testing. The sets include 3 or 5 hand-held probes with built-in preamplifier covering the frequency range from <1 MHz to approx. 3000 MHz.
The probes of the basic set HZ540 include one magnetic field probe, one electric field probe, and a high impedance probe. In addition to the HZ550 features an optional μmagnetic field probe and an antenna. All probe outputs are matched to the 50 Ω inputs of spectrum analyzers or RFreceivers. 
| |  | HZ541 *
1GHz VSWR Bridge
This unit is used to measure the voltage standing wave ratio (VSWR) and the reflection coefficient of a device under test with an impedance of 50 Ω.
Typical test objects include attenuators, terminations, frequency switches, amplifiers, cables and mixers. The measurement range is specified from 150 kHz…1 GHz/100 kHz…3 GHz.

Technical specifications (temperature range from +10 °C to +45 °C) 
| Frequency range: | 150 kHz…1.05 GHz | | Impedance: | 50 Ω | | Directivity: | › 28 dB (150 kHz…300 kHz) › 35 dB (300 kHz…1 GHz) | Reflection loss at DUT port: | ›20 dB | Insertion loss IN→ OUT: | 20 dB (150 kHz…300 kHz) | | IN→ OUT: | 17 dB (300 kHz…1 GHz) | | IN→ DUT: | 1.7 dB | | DUT→ OUT: | 16 dB | | Max. Power Dissipation: | +26 dBm | | Connectors: | N (female) | Dimensions (W x H x D, without connectors): | 151.5 x 38 x 29.5 mm | | | | | Weight: | approx. 650 g | | Temperature range: | +10 °C…+45 °C |

HZ525 (Termination 50 Ω 1W), N male to N male (2 ea.),Carrying case (265 x 225 x 50mm WxHxD) 
* Product discontinued; Successor: HZ547 
| |  | HZ547
VSWR Bridge
This unit is used to measure the voltage standing wave ratio (VSWR) and the reflection coefficient of a device under test with an impedance of 50 Ω.
Typical test objects include attenuators, terminations, frequency switches, amplifiers, cables and mixers. The measurement range is specified from 150 kHz…1 GHz/100 kHz…3 GHz.

Technical specifications (temperature range from +10 °C to +45 °C) 
| Frequency range: | 100 kHz…3 GHz | | Impedance: | 50 Ω | | Directivity: | › 28 dB (100 kHz…300 kHz) 35 dB (300 kHz…1 GHz) › 30 dB (1 GHz…3 GHz) | Reflection loss at DUT port: | ›20 dB | Insertion loss IN→ OUT:20 dB (100 kHz…300 kHz) | | IN→ OUT: | 18 dB (300 kHz…3 GHz) | | IN→ DUT: | 1.7 dB | | DUT→ OUT: | 16 dB | | Max. Power Dissipation: | +26 dBm | | Connectors: | N (female) | Dimensions (W x H x D, without connectors): | 150 x 68 x 29.5 mm | | | | | Weight: | approx. 650 g | | Temperature range: | +10 °C…+45 °C |

HZ525 (Termination 50 Ω 1W), N male to N male (2 ea.),Carrying case (265 x 225 x 50 mm WxHxD) 
| |  | HZ560
Transient Limiter
The HZ560 Transient Limit protects the input circuits of spectrum analyzers and test receivers.
The input of the Transient Limiter is connected via BNC cable to the signal source. The output can be connected directly to the spectrum analyzer. 
Technical specifications at 23 °C ± 2 °C 
| Frequency range: | 150 kHz…30 MHz a = 10 dB + 1.5/0.5 dB at f <1 kHz a ≥90 dB at f <10 kHz a ≥50 dB | | Insertion loss: | 10 dB (+1.5/0.5 dB) | | Max. input level: | +33 dBm (2 W, average) | | Max. input voltage: | ±50 Vdc | | VSWR: | 1.5:1 or better | | Connections: | BNC (input and output) | | Dimensions: | 67 x 32 x 32 mm (W x H x D) |

| |  | HZ575
Converter
HZ575 is a 75 Ω to 50 Ω converter enabling measurement in 75 Ω systems in connection with 50 Ω input impedance spectrum analyzers.
The 75 Ω input is a 75 Ω BNC socket which is AC coupled internally. The output is a 50 Ω N male connector which is DC coupled. HZ575 can also be used for reverse operation converting 50 Ω to 75 Ω. 
Technical specifications 
| Frequency range: | 5MHz…1.2GHz | | Insertion loss: | less than 1dB | | Max. Level/Voltage at 75Ω connector: | +10dBm / ±20Vdc | | Max. Level/Voltage at 50Ω connector: | +10dBm / 0Vdc | | Dimensions: | 25 x 25 x 58mm (W x H x D) | | Weight: | 100g |

| |  |
|
 |